Destroy the wasted materials or chemical uses in pharmaceuticals

Destroy the wasted materials or chemical uses in pharmaceuticals through Primary & Secondary combustion Chamber’s with working  temperatures are 850° C & 1100° C or 1200° C & 1400° C. The incinerator design must meet with ISO, OSHAS, Emission  Standards, Norms and Guidelines. The incinerator design must have heat recovery system and low fuel consumption system while  incineration.  The machine should have following features in its respective parts –  Feeding system Automatic/ and manual control system Automatic heating control system Easy maintenance  Outdoor type IP grade material Heat recovery system Low fuel consumption system  Combustion chamber dual type with heat recovery system Burner system with economizer / low fuel method Scrubbing system as per regulation Easy dust collecting system Chimney (height 50 meter) Record printing system Incinerators to be suitable for the professional disposal of clinical & medical waste / garbage with a higher load capacity in the range of approximately 1000-1500 Kg.  The durable, self-contained  incinerators shall offer an effective and highly efficient, safe disposal and to be manufactured according to applicable international directives, e.g. CE, EU, etc. Type of Fuel: Diesel or Petrol or Natural Gas. Temperature controlled, efficient burner for optimum fuel economy. Units to be pre-assembled, pre-piped, pre-wired and tested before transport / export. Within the framework of an environmental and medical equipment & technology consultation and joint purchasing, this Procurement Bureau invites applicants for pre-qualification in the aim of primarily selecting capable companies to bid for the above tender.

Mobile Diesel Fired Incinerator in container

Mobile Diesel Fired  Incinerator in container,  supplied with the following specifications: complete with constant ventilation fans for extraction,  factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping.  Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications. Installed in Container (ISO) : 20” or its nearest equivalent model “ Tender Technical Specification Destruction rate of 50kg/hr Hot Hearth Principle Refractory insulation: a. Silicon carbide floor b. Minimum 22mm insulation thickness c. Brick lined Refractory insulation d. Three layers of refractory insulation e. Temperature Rating 1650 deg.C f. 42% alumina fire bricks Primary Chamber: a. 120Kw Burner  b. Dedicated independent fan system, damper controlled.  c. Thermostatic Sensor  d. Dimensions – 700mm x 700mm x g00mm e. Square Chamber with curved floor for liquid centralization Hot Hearth Chamber: a. 120Kw Burner b. Thermostatic Sensor  c. Minimum Temperature of 1100 deg.C as per WHO guidelines.  d. Two second retention time – Proven with CFD modeling. Steel Construction: a. constructed from 8mm & 1Omm steer plate  b. Painted two pack paint system, red with black flashing Control Panels: a. Door dimensions 700mm x 700mm b. Front mounted ash collection box. Control Panels: a. AiController b. Plug and play  c. Threezone monitoring of: i)Primary chamber               ii) Secondary chamber               iii) Hot hearth d. Digital display …

200 BEDS HOSPITAL INCENERATOR TECHNICAL INFORMATIONS

1) Policy – Waste disposal management shall be taken special note to prevent hospital infection. – Infections wastes shall be managed, stored strictly and burned by a incinerator located at hospital site.   2) Waste Disposal Plan a) Classification – Medical wastes in hospital are …

For the Supply, installation & commissioning of a Medical Waste Incinerator

i. Waste type Health care waste ii. Waste density 125 to 350Kg/M3 iii.. Waste Calorific Value 4000 KCAL/Kg iv. Moisture content 10-25% v.  Estimated ash  residue 5-10% vi.  Nominal capacity  100Kg/hour batch load vii.  Secondary chamber 2 seconds @ 1100°C viii. Environmental Environmental Management Coordination Act, 1999 and in particular, Waste management regulations, 2006  2 Equipment 2.1 Primary Combustion Chamber        The primary combustion chamber is the main structure of the               incinerator, fabricated from mild steel plate and stiffened with               rolled steel sections. It is carried from the floor level on a               substantial steel support frame. Internally the shell is lined with               calcium silicate insulation and a hot face combination of super               duty brickwork or high strength castable.        The primary combustion chamber must ensure minimum exit               temperature is not less than 850°C. One Manual Load Incinerator comprising:      Manual Loading door (heavy duty steel door with appropriate               refractory lining)      Horizontal solid hearth, refractory lined primary combustion               chamber. Approximate dimensions 800 mm diameters x 2100mm               long …

SOLID WASTE INCINERATOR Feeding Capacity 200 to 220 Kg

Burn Rate * 60 Kg / hr Ingredients to be burned Cotton, Rubber, PVC Sheets, PE Gloves, Oil, Plastic Bottles, Paper etc. Chambers * Dual Chamber. 1: Primary Controlled Air 2: Secondary Excess Air Temperature Monitoring Required Temperature Control to Primary & Secondary Chambers Required System Status & Alarms Required for all necessary parameters. Fittings & Accessories Complete Package is required ( Including Nozzles & Flanges etc.) Installation Requirements. As low as possible . Almost Plug & Play type. Dimensional Sketch, Operation & Installation Manuals. Required Off – Gas System Required Heat Insulation Required for indoor installation Delivery Karachi Sea Port – Pakistan The details of Components of incinerator is as follows: Component Name     Features              Range.        Primary Chamber Temperature Required* 800 – 1000 deg C. Heating Source Natural Gas      Secondary Chamber Temperature * 1100 – 1300 deg. C Heating Source Natural Gas + Propane or Fuel Oil as an additional source Off – Gas Residence Time  2 Seconds. …

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR

SPECIFICATIONS OF A DIESEL FIRED INCINERATOR 1.0 INCINERATOR, DIESEL, FIRED. Specifications Indicate if item offered complies with each specification.  1.1 General description      ▪      The incinerator should be a modern waste disposal unit, designed              to bum medical waste in a clean and environmentally efficient              manner. It should employ a temperature based logic control system              to provide optimum control of the operating conditions and              incorporate a high capacity thermal oxidizing secondary chamber.              It should be designed to retain the exhaust gases, for at least 2              seconds to ensure the unit’s effective destruction of the combustion              products.      ▪      All the  incinerators to be supplied and installed meet the              Waste Management Regulation 2006, legal notice No. 121 of              29th September 2006 and in particular 3rd schedule regulation              (26, 47) pertaining classification, standards, criteria, and              procedure for installing and operating  incinerators.      ▪      The capacity of the incinerator required should be to the               specifications with a capacity to burn 100kgs/Hr.      ▪      The incinerator shall be run on a three-phase power supply               (mains).      ▪      For the technical evaluation, not only the treatment plant but               the entire system will be considered. It will be the responsibility               of the Bidder to supply a full system, including all eventually               additionally necessary secondary systems and additional               equipment.      ▪      The system offered shall be designed to operate normally under               the conditions of the purchaser’s country. The conditions include               Power Supply, Climate, Temperature, Humidity, etc.      ▪      The Bidder must provide a warranty for one year.      ▪      All text, parameter etc. on all control operating interfaces as               well as on information displays and on print-outs shall be in               English language.      ▪      The Bidder is responsible for all permits and approvals for               importation. The Bidder shall provide all the necessary               documentation in order to facilitate the legal requirements for the               installation and putting into use of the equipment.      ▪      Period of Execution is 90 days from contract signature for  …

Fw: waste disposal range treatment capacity: 35 kg incinerator

 Suitable models for required waste disposal range.  Combustion efficiently per hour based on 08hrs operation and its fuel category  installation method C Mobile type/ possibility of structured inside container / structured in permanent base   Fuel consumption details consisting electricity  Capacity: 20KG/Hr, Temp Range: 600 Deg. C C 1100 Deg. C  Fuel Supply: Natural Gas/Diesel Dual Combustion Chamber Complete Scrubbing System (Dual  Resultant Gas Washer), Dual Blower, Chimney Height: 8m Electric Supply: 220/240Volt, Single Phase  Waste treatment capacity: 35 kg / h The combustion chamber is thick steel plate (3 to 10 mm ) with reinforcements, specially built . Front loading with watertight door mounted on hinges, locking screw wheel , flexible gasket and an insulating refractory lined  . An internal lining of refractory concrete containing 42% of H2 03 (alumina ) and 100 mm thick walls. fibrous insulation panels made ??of calcium silicate with a thickness of 75mm . Automatic Burner ( diesel or gas must be specified in the order ) with flames diving in one piece monoblock with an electronic  ignition system , permanent ventilation control valve and isolation valve. combustion floor made ??in carborundum , preventing binding of glass and slag. Equipped with two (02) chambers Fuel: Gas or butane gas Power supply: 220 V 50 Hz single-phase Capacity 100 Kg (0.18 m3) Electric starter ・       The room dimensions are 6.64 m width x 6.61 m length x 6.03 m height at lowest point/per one incinerator. Are these  dimensions sufficient for complete one medical incinerator 150 kg/hours (1.5ton/day). ・       Please, provide complete data about chemical consumption required for waste incineration, gas emission treatment  ,liquid waste and generated soiled wastes handling and/or, treatment . ・       Please, confirm that the exhaust gases are treated by alkaline scrubbing (wet or dry).

Solid waste incinerator placed in a container

Solid waste incinerator, productivity 100kg/h placed in a container.  Dimensions: 2,45×12,2m and 2,9m in height.   Operates natural gas with the pressure of 0.005 MPa and consumption of 0,21-0,23 m3 per kg of waste. Installed power C 55 kW. Total 3 units. Fuel capacity:200l or more Incinerator has a temperature monitoring system in place Wet scrubber capable of removing sulpur dioxide in the fumes Water capacity of 2000l or more Incinerator temeprature above 950 degree celsius Incinerator used a dual chamber system for incinerator Capacity per hour at least 25kg 1. A combustion chamber : a. watertight door for manual loading of waste. b . A burner start is limited to inflammation of waste . 2. A camera post-combustion gases : a. burner combustion , low power . b . An injection device air for total recombustion of the gases . c . An input device cooling air of the combustion gases. d . A smoke evacuation duct .   3. A control panel ensuring complete combustion cycle .   The incinerator meets as indicated on waste incineration . They will not burn plastics, packaging except that the amount so small that gases need not receive any treatment, secondary combustion chamber to 1100C handles everything ..   Water waste incinerator, productivity up to 3m3/h and placed in a modular building. Dimensions: 8,2×5,9m and 5m in height.  Operates natural gas with the pressure of 0,016 MPa and consumption of 0,35m3 / kg of drainage. Installed power C 35 kW. Total 1 unit.