Incinerator Fire flames in primary chamber

The incinerator should be a modern waste disposal unit, designed to bum medical waste in a clean and environmentally efficient manner. It should employ a temperature based logic control system to provide optimum control of the operating conditions and incorporate a high capacity thermal oxidizing secondary chamber. It should be designed to retain the exhaust gases, for at least 2 seconds to ensure the unit’s effective destruction of the combustion products.
The primary combustion chamber is the main structure of the incinerator, fabricated from mild steel plate and stiffened with rolled steel sections. It is carried from the floor level on a substantial steel support frame. Internally the shell is lined with calcium silicate insulation and a hot face combination of super duty brickwork or high strength castable.
The primary combustion chamber must ensure minimum exit temperature is not less than 850°C.
One Manual Load Incinerator comprising:

Manual Loading door
Horizontal solid hearth, refractory lined primary combustion chamber. Approximate dimensions 800 mm diameters x 2100mm long
Full sized bulk load/ash removal door
1 off diesel-fired ignition burner ― temperature controlled
1 off combustion air supply fan and distribution system, automatic control
High capacity secondary combustion chamber with residence time not less than 2 seconds @ >850°C
1 off diesel-fired afterburner ― temperature controlled
Control panel ― automatic operation
Temperature indication primary and secondary chambers 0-1200°C 
Refractory lined flanged chimney to a height of 10M above ground level
50kg/hour at a nominal calorific value of 4,000 kcal/kg and an average bulk density of I20kg/ M3 for general waste and l60kg/ M3 for health care waste.

Should be manufactured from refractory lined mild steel or high quality air-cooled stainless steel. The chimney/stack should have a minimum height of 10 meters above ground level. 

Fully packaged oil type, complete with electric ignition and flame failure controls, wired with continuous running fan and complete with all valves, fan and motor.
Maximum rating:            at least 450kW/hour
Burner:                            arranged for on/off operation
Maximum consumption: at least 6 litres/hour
Average consumption:    at least 3 litres/hour

Fully packaged oil type, complete with electric ignition and flame failure controls wired with continuous running fan and complete with all valves, fan and motor.
Maximum rating: at least 450kW/hour
Burner: arranged for on/off operation
Maximum consumption: at least 9 litres/hour
Average consumption: at least 4.5 litres/hour