refractory lining of incinerators

Must Required the Composition of the refractory lining:

Refractory bricks :

. Thickness : 110 mm
. Maximum temperature : 1,400 °C
. Nature : 42% of Al203

Insulator :

. Thickness : 50 mm
. Maximum temperature : 1,000 °C
. Nature : Calcium silicate

Combustion burner :

* The combustion chamber should be composed of one hearth of combustion.

* The combustion hearth should be fitted with one burner enabling to assure a correct combustion temperature for the complete destruction of the waste.

* Burner should be  mono-bloc casing type with horizontal flame, ignition and electronic ignition safety, permanent ventilation, control electrovalve and insulation valve.

Air Supply Fan:

* Electro-ventilator distributes the primary and secondary air in the incinerator.

* This combustion hearth should be equipped with primary air nozzles (8 nozzles) to assure the perfect combustion. 

* The air injection should be done with a high pressure of 220 mm H20.

* The pressure allows to pierce the burning waste bulk and to avoid the unburned ratio.

* The adjustment of air rates should carried out through valves and servomotor according to the automatic cycle controls.