document for Incinerator machine Model TS30

HICLOVER Medical Environmental Incinerators|Phone/WhatsApp:+86-13813931455  Medical Waste Incinerator TECHNICAL SPECIFICATION FOR SUPPLY AND INSTALLATION OF MEDICAL  WASTE INCINERATOR AT MAHAMA HEALTH CENTER …

About Us HICLOVER | HICLOVER.COM

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and …
HOSPITAL WASTE INCINERATOR 50-60KG / HR

HOSPITAL WASTE INCINERATOR 50-60KG / HR

The Incinerator (waste management system ) is a turn-key project which will compromise a  hospital grade incinerator, allied accessories for proper disposal of  hospital solid waste material and imputed human organs.  The incinerator shall also be suitable for plastic, paper, textile and rubber dry and wet infectious waste of the  hospital. The unit shall be of high performance to  be opened continuously for at least 08 C 12 hours daily. The Primary source of fuel will be natural gas (must be compatible with LPG as backup source with vaporizers) combustion with smokeless emissions. For ensuring the clean environment, it should strictly comply with EPA standards having EIA certifications  The incinerator system should be based on at least  design and recently manufactured having following specifications:- (1)    Burning Capacity. Continuous feeding and burning capacity of 50-60 kg/ hour or better having volume of 500 liters or more. YES, 50-100kgs/hr. 560 Liters (2)    Construction (a)    Primary Chamber i.                     Rectangular shape dual chamber construction YES ii.                   The feeding door should be in accordance to load size and should be front loaded or side loaded (Manual/ Automatic). YES iii.                  The steel sheet shall be at least 6-8mm thick & 10-12mm or more from front with Heat resistant paint. YES. 8MM MAINBODY. 15MM PARTIAL STRENGTHENING iv.                 The internal surface of the incinerator shall be lined with non-cracking refractory bricks (high content of Aluminum or  suitable material) along with isolation bricks to withstand a temperature of 1400°C backed by thermal insulation. HOT FACE, HIGH ALUMINUM FIREBRICK 55% OF AL203,1750°C GRADE. CODE FACE, HIGH RATE REFRACTORY CERAMIC FIBER, 1050°C GRADE. (b)   Post Chamber. Post combustion chamber is lined with high thermal insulating materials with a thickness of 150mm or more of refractory bricks and 85mm of insulator. …
INCINERATOR AT NAIROBI SAFARI WALK

INCINERATOR AT NAIROBI SAFARI WALK

Vertical closed furnace combustion chamber incinerator   Medical waste, disposable syringes, infusion sets processing, cotton yarn, the operating room, the residual limb, waste rubber gloves, protective clothing and infectious and harm venereal  hospital bed supplies, general wastes.