NATURAL RESOURCES CONSERVATION AUTHORITY: AIR QUALITY REGULATIONS (2006)

NATURAL RESOURCES CONSERVATION AUTHORITY: AIR QUALITY REGULATIONS (2006)
Emission Standards for New Sources
SEGMENT STANDARDS FOR NEW SOURCES
Pollutant Value
Municipal/Biomedical  Incinerators PM 200 mg/m3 (c)
CO 100 mg/m3 (c)
SO2 300 mg/m3 (c)
VOC 20 mg/m3  as C (c)
Cement Kilns burning hazardous and non-hazardous wastes as supplementary fuel PM 20 mg/Rm3 (d) for that portion of the fuel resulting from combustion of waste fuel
PCCD &PCDF 0.5 ng/m3 (d)
HCI 50 mg/Rm3 (d)
Sum of Sb,Cu, Pb, Mn, V, Zn 1.5 mg/Rm3 (d)
Sum of As, Cr, Co, Ni, Se, Te 0.15 mg/Rm3 (d)
Sum of Cd, Hg, Ti 0.15 mg/Rm3 (d)
(a) 20K, 101.3 kPa, dry gas
(b) (H) High heat release rate means a heat release rate greater than 730,000 J/sec-m3 (70,000 Btu/hour-ft3). (L) Low heat release rate means a heat release rate of 730,000 J/sec-m3 (70,000 Btu/hour-ft3) or less. Heat release rate means the steam generating unit design heat input capacity (in MW or Btu/hour) divided by the furnace volume (in cubic metres or cubic feet); the furnance volume is that volum bounded by the front furnance wall where the burner is located, the furnance side waterwall, and extending to the level just below or in front of the first row of convection pass tubes. STD = allowable NOx emissions (percent by volume at 15% oxygen and on a dry basis. Y = manufacturer’s rated heat rate at manufacturer’s rated load (kilojoules per watt hour) or, actual measured heat rate based on lower heating value of fuel as measured at actual peak load for the facility. The value of Y shall not exceed 14.4 kilojoules per watt-hour. F=NOx emission allowance for fuel-bound nitrogen as defined below.
Fuel-bound nitrogen
(percent by weight) F 
(NOX percent by volume)
N
0.015
0.1
N>0.25 0.005
Where: N = the nitrogen content of the fuel (percent by weight). Or: Manufacturers may develop custom fuel-bound nitrogen allowances for each gas turbine model they manufacture.
(c) 273K, 101.3 kPa, dry gas
(d) Rm3 refer to standard conditions of 11% O2 , dry basis
Ambient Air Quality Standards for Jamaica
POLLUTANT AVERAGING TIME STANDARD (Maximum concentration in µg/m3)1 
Total Suspended Particulate Matter (TSP) (a) Annual 
24hr 60
150
PM10 (b) Annual
24hr 50
150
Lead Calendar Quarter 2
Sulphur Dioxide Annual
24hr
1hr 80 Primary; 60 Secondary (c)
365 Primary; 280 Secondary
700
Photochemical Oxidants (ozone) 1hr 235
Carbon Monoxide 8hr
1hr 10,000
40,000
Nitrogen Dioxide Annual 100
1 Note that the regulations should have specified that all air quality measurements expressed in mass per unit volume are to be corrected to 25C and 101.3 kilopascals.
TSP – all particles and aerosols with aerodynamic diameter of 100 micrometers or less and can be measured by the high volume sampling method.
PM10 refers to particles with an aerodynamic diameter of 10 micrometres or less as measured by the PM10 sampler.
The secondary standards for sulphur dioxide are designed to protect public health and welfare. They represent the long-term goal for air quality and provide the basis for an anti-degradation policy for unpolluted areas of the country and for continuing development of pollution control technology. 
Ambient Air Quality Guidelines for Priority Air Pollutants
Chemical Chemical Abstract Service No. Concentrations in µg/m3
1hr 24hr Annual
1,1,2,2-tetrachloroethane 79-34-5 0.2
1,1,2-trichloroethane 79-00-5 0.6
1,2-dichloroethane 107-06-2 0.4
1,3-butadiene 106-99-0 0.04
1,3-dichloropropene 542-75-6 50 20
2,3,7,8-tetrachlorodibenzo (p)dioxin 1746-01-6 2.3×10-7
2,4-dinitrotoluene 121-14-2 0.05
2-nitropropane 79-46-9 50 20
Acetaldehyde 75-07-0 1,250 500
Acetonitrile 75-05-8 375 150
Acrolein 107-02-8 58.75 23.5
Acrylic Acid 79-10-7 2.5 1
Acrylonitrile 107-13-1 250 100
Aldrin 309-00-2 0.002
Ammonia 7664-41-7 9,000 3,600
Aniline 62-53-3 2.5 1
Antimony &compounds 7440-36-0 62.5 25
Arsenic &compounds 7440-38-2 0.75 0.3
Benzene 71-43-2 1
Benzo(a)pyrenr 50-32-8 0.00275 0.0011
Benzyl chloride 100-44-7 0.2
Beryllium &compounds 7440-41-7 0.0013
Cadmium &compounds 7440-43-9 5 2
Calcium oxide 1305-78-8 25 10
Carbon dioxide (process emissions) 124-38-9
Carbon disulphide 75-15-0 1,750 700
Chemical Chemical Abstract Service No. Concentrations in µg/m3
Carbon tetrachloride 56-23-5 6 2.4
Chlordane (technical) 12789-03-6 12.5 5
Chlorinated dibenzo-p-dioxins (cdds) NA 12.5 pg TEQ/m3 5pg TEQ/m3
Chlorine dioxide 10049-04-4 75 30
Chloroform 67-66-3 1,250 500
Chromium, hexavalent compounds 18540-29-9 3.75 1.5
Chromium, trivalent compounds 16065-83-1 3.75 1.5
Cobalt &compounds 7440-48-4 0.12
Copper &compounds 7440-50-8 125 50
Cresols 1319-77-3 187.5 75
DDT 50-29-3 0.1
Dieldrin 60-57-1 0.002
Endrin 72-20-8
Ethylene dibromide 106-93-4 7.5 3
Ethylene dichloride 107-06-2 5 2
Ethylene glycol 107-21-1 31,750 12,700
Formaldehyde 50-00-0 162.5 65
Heptachlor 76-44-8 0.008
Hexachlorobenzene 118-74-1 0.02
Hydrogen chloride 2099-048 100 20
Hydrogen sulphide 7783-06-4 2.5 1
Lead 7439-92-1
Manganese &compounds 7439-96-5 119
Mercaptans (as methyl mercaptan) 74-93-1 50 20
Mercury &compounds 7439-97-6 5 2
Mercury alkyl 7439-97-6 1.25 0.5
Methyl bromide 74-83-9 3,375 1,350
Methylene chloride 75-09-2 550 220
Mirex 2385-85-5
Nickel &compounds 7440-02-0 5 2
Nitric acid 7697-37-2 87.5 35
Nitrogen oxides as nitrogen dioxide 10102-44-0 400
Chemical Chemical Abstract Service No. Concentrations in µg/m3
Polycyclic Aromatic Compounds
P-dichlorobenzene 106-46-7 237.5 95
Pentachlorophenol 87-86-5 250 100
Phenol 1108-95-2 250 100
Polychlorinated biphenyls 1336-36-3 0.375 0.15
Polychlorinated dioxins and furans 0.02 pg/m3#
P-xylene 106-42-3 5,750 2,300
Quinoline 91-22-5 0.003
Selenium &compounds 7782-49-2 25 10
Sodium hydroxide 1310-73-2 25 10
Styrene 100-42-5 2,500 1,000
Sulphuric acid 7664-93-9 1 23.8
Sulphuric acid 7664-93-9 87.5 35
Tetrachloroethylene 127-18-4 900 360
Toxaphene 8001-35-2 0.03
Trichloroethylene 79-01-6 57.5 23
Vinyl cgloride 75-01-04 1 0.2
Vinylidene chloride 75-35-4 87.5 35
Xylenes 1330-20-7 5,750 2,300
Zinc and compounds 7440-66-6 12
Electrically operated incinerator : small model
In a simple design with a metal steel drum electric. including:
 A cage for receipt of biomedical waste;
 A combustion chamber with fireplace with a filter to retain ashes;
 A cover;
 An air supply;
A turbine  allowing the supply of the air.
Combustion temperature: 1800 ° C. Compliance with European standards.
Comes with all necessary accessories