Biomedical Waste Incinerator, 10-15 kg Manufacturer: Brand: Type / Model: Country of Origin: Description of Function The Biomedical Waste Incinerator is used for Incineration of each type of Biomedical Waste. The Disposal of such Biomedical waste is a very important as it is a dangerous wastes for human life, and It is only possible with a perfect incinerator. Operational Requirements It shall be operated by manual and automated mode. The combustion efficiency (CE) shall be at least 99.00%. The combustion efficiency is computed as follows: C.E.= __%CO2______ x 100 %CO2 + %CO Emission Standards: Lower emission rates are preferred. Parameters Concentration in mg/Nm3 (12% CO2 correction Max total dust 30mg/m3 Max Sulphur Dioxide 200mg/m3 Max Nitrogen dioxide 400mg/m3 Max Carbon 100mg/m3 Monoxide Minimum stack height shall be 30 metres above ground. Volatile organic compounds in ash shall not be more than 0.01%. System Configuration Biomedical Waste Incinerator, complete unit. Technical Specifications Incinerator: It shall be Electrical or Diesel Fired Incinerator or Controlled Air & pyrolytic. Type of Waste: Biomedical Waste It shall have burning capacity 10-15 kg/hr. Fuel: Diesel Burner: Monoblock fully automatic burners. Temperature: Primary Chamber 800 ± 50 oC, Secondary Chamber 1050 ± 50 oC. Type of Waste: Biomedical waste with moisture content up to 85%. Destruction Efficiency: 99%. It shall have separate digital display of temperature for both chambers. It shall have provision for measuring primary & secondary chamber temperatures using external thermo coupler. Secondary chamber gas residence time shall be minimum 1 second at 1050 oC. Primary Chamber: Type: Static Solid Hearth …